The Annals
home help contact us subscription past issues search current issue
 QUICK SEARCH:   [advanced]


     


DICP, The Annals of Pharmacotherapy: Vol. 23, No. 12, pp. 999-1004.
© 1989 Harvey Whitney Books Company.
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Articles Ahead of Print
Right arrow [Order Reprint]
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wooding-Scott, R.
Right arrow Articles by Slaughter, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wooding-Scott, R.
Right arrow Articles by Slaughter, R.


Research Articles

Comparison of assay procedures used to measure total and unbound concentrations of quinidine

RA Wooding-Scott, IM Darling, and RL Slaughter

Individualized quinidine dosing through the assessment of serum concentrations is warranted because of the wide variability observed in its pharmacokinetic behavior and its reported narrow therapeutic index. The free fraction of quinidine also varies widely. Thus the development of procedures that could be widely used to determine quinidine free concentrations would be highly desirable. It was the purpose of this study to evaluate several procedures available to determine total serum quinidine concentrations (rate nephelometry [ICS], homogenous enzyme immunoassay [EMIT], and high-performance liquid chromatography [HPLC]). Furthermore, in samples from 46 patients, equilibrium dialysis and ultrafiltration procedures were compared for their ability to estimate quinidine free fraction. Finally, unbound concentrations of quinidine were compared using a modified EMIT procedure and a standard HPLC method to quantitate quinidine in ultrafiltrates from patient samples. For the measurement of total quinidine concentrations, reasonable agreement was seen when EMIT and ICS systems were compared with HPLC (ICS = 1.03.HPLC + 0.96, r = 0.93; EMIT = 1.08.HPLC + 0.38, r = 0.93) The mean errors, however, for these procedures were high (ICS +70 percent, range +7 to +233 percent; EMIT +35 percent, range 0 to 110 percent). Quinidine free fractions (QFF) determined by equilibrium dialysis (E) and ultrafiltration (U) showed good agreement (QFF(U) = 1.11.QFF(E) +0.0; r = 0.96). Unbound quinidine concentration determined by EMIT analysis of ultrafiltrate substantially overestimated the values obtained by HPLC analysis (mean error by EMIT 104 +/- 59 percent). It is concluded that HPLC is the method of choice for determining both total and unbound serum quinidine concentrations.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
Clin. Chem.Home page
R. Valdes Jr., S. A. Jortani, and M. Gheorghiade
Standards of laboratory practice: cardiac drug monitoring
Clin. Chem., May 1, 1998; 44(5): 1096 - 1109.
[Abstract] [Full Text] [PDF]




homecopy help contact us subscription past issues search current issue
Copyright © 1989 by Harvey Whitney Books Company.