The Annals Take our Readership Survey!
home help contact us subscription past issues search current issue
 QUICK SEARCH:   [advanced]


     


The Annals of Pharmacotherapy: Vol. 29, No. 11, pp. 1091-1095.
© 1995 Harvey Whitney Books Company.
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Articles Ahead of Print
Right arrow [Order Reprint]
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Coodley, E.
Right arrow Articles by Neutel, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Coodley, E.
Right arrow Articles by Neutel, J.


Research Articles

Bioelectrical impedance analysis as an assessment of diuresis in congestive heart failure

EL Coodley, JL Segal, DH Smith, and JM Neutel

OBJECTIVE: To compare changes in bioimpedance parameters and calculated total body water (TBW) with conventional measurements used to assess the efficacy of diuretic therapy in the treatment of heart failure. SETTING: A Veterans Affairs tertiary care, teaching hospital. SUBJECTS: Twelve patients with New York Heart Association (NYHA) class III congestive heart failure (CHF). DESIGN: Prospective, consecutive sample, cohort, open label. INTERVENTIONS: Parenterally administered furosemide; clinically dictated, outcome-oriented, adjunctive therapy of CHF. OUTCOMES: Bioelectrical impedance analysis (BIA) parameters, measured volume of diuresis and changes in body weight, defined clinical endpoints (NYHA criteria). RESULTS: Three days of diuretic therapy with furosemide (oral and/or intravenous) for CHF was associated with a measured weight loss of 4.1 +/- 0.6 kg and statistically significant increases in resistance and reactance of 20.8% +/- 2.7% and 22.7% +/- 6.1%, respectively (p < 0.005). Calculated TBW using BIA parameters and standard equations decreased on average by 6.1 +/- 0.6 L or 11.2% +/- 1.1% (p < 0.001). A significant inverse correlation was observed between change in measured body weight and total body reactance (p = 0.02). CONCLUSIONS: Single-frequency BIA appears to have limited clinical usefulness as a method of assessing diuretic therapy in the management of CHF. Its greatest usefulness appears to lie in the assessment of serial changes in individual patients and patient populations that are physiologically or metabolically homogeneous. Further studies are needed to establish the validity of BIA in patients with decompensated CHF.





homecopy help contact us subscription past issues search current issue
Copyright © 1995 by Harvey Whitney Books Company.