The Annals the journal of Pharmacy Technology
home help contact us subscription past issues search current issue
 QUICK SEARCH:   [advanced]


     


The Annals of Pharmacotherapy: Vol. 33, No. 4, pp. 416-419. DOI 10.1345/aph.18334
© 1999 Harvey Whitney Books Company.
This Article
Right arrow PDF
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Articles Ahead of Print
Right arrow [Order Reprint]
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Glover, M.
Right arrow Articles by Wolfsdorf, J
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Glover, M.
Right arrow Articles by Wolfsdorf, J


Research Articles

The use of alteplase in a newborn receiving extracorporeal membrane oxygenation

ML Glover, MT Camacho, and J Wolfsdorf

OBJECTIVE: To present a case of the use of alteplase for the successful resolution of an upper extremity occlusion in a newborn receiving extracorporeal membrane oxygenation (ECMO). CASE SUMMARY: A two-day-old full-term Hispanic girl receiving ECMO support developed a left upper extremity occlusion distal to the brachial artery. Alteplase therapy was initiated with a bolus dose of 0.48 mg/kg followed by a continuous infusion of 0.27 mg/kg/h for three hours. A repeat Doppler ultrasound revealed little improvement, resulting in continuation of alteplase therapy at an infusion rate of 0.27 mg/kg/h for an additional three hours. At the completion of the infusion, perfusion was greatly improved with palpable radial pulse present. While remaining on ECMO support, a brain ultrasound approximately 13 hours after alteplase therapy revealed a grade I right caudate head hemorrhage with normal ventricles. ECMO support was discontinued during the next 24 hours, with a repeat brain ultrasound three days later indicating no acute hemorrhage, normal ventricles, and almost complete resolution of the intraventricular hemorrhage. The neonate was discharged 19 days after discontinuing ECMO support. DISCUSSION: Patients receiving ECMO support are at risk of hematologic complications, including thrombi formation. Moreover, limited information is available regarding the most appropriate thrombolytic therapy for patients receiving ECMO support. Alteplase is an attractive thrombolytic agent given its antigenicity, clot specificity, and pharmacokinetic profile. However, both ECMO support and thrombolytic therapy are risk factors for the development of intraventricular hemorrhage, which our patient developed. Therefore, close monitoring of patients receiving ECMO support and alteplase therapy is essential given the potential for hematologic adverse effects. CONCLUSIONS: Alteplase is an effective thrombolytic agent in neonates receiving ECMO support. Additional experience with alteplase is necessary to determine the optimal dose and duration of therapy in this patient population.





homecopy help contact us subscription past issues search current issue
Copyright © 1999 by Harvey Whitney Books Company.