The Annals Take our Readership Survey!
home help contact us subscription past issues search current issue
 QUICK SEARCH:   [advanced]


     


The Annals of Pharmacotherapy: Vol. 36, No. 3, pp. 380-385. DOI 10.1345/aph.1A253
© 2002 Harvey Whitney Books Company.
This Article
Right arrow PDF
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Articles Ahead of Print
Right arrow [Order Reprint]
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rigelsky, J.
Right arrow Articles by Streetman, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rigelsky, J.
Right arrow Articles by Streetman, D.


Research Articles

Accuracy of the avosure PT pro system compared with a hospital laboratory standard

JM Rigelsky, HM Choe, DM Curtis, MJ Brosnan, S Mitrovich, and DS Streetman

OBJECTIVE: To compare international normalized ratio (INR) values obtained using the AvoSure PT Pro point-of-care (POC) system with those obtained using a standard laboratory method. METHODS: Forty-one INR values obtained from the POC system were compared with those obtained from a standard laboratory method. The POC method was evaluated for both laboratory and clinical agreement. To evaluate laboratory agreement, various analyses were used, including mean-squared prediction error (MSE) and mean prediction error (ME), Bland-Altman analysis, correlation, and paired t-test comparing group INR means. For clinical accuracy, discrepant pairs were identified and evaluated to determine whether dosage adjustments would have been needed based on values obtained. RESULTS: The POC system demonstrated modest precision (MSE = 0.147, 95% CI 0.065 to 0.228) and relatively little bias (ME = 0.090, 95% CI -0.025 to 0.205). Bland-Altman analysis also suggested good agreement at average INRs from 2.0 to 3.0. At average INR values >3.0, the POC system consistently overestimated INR. Values obtained with the POC system were significantly correlated with those obtained from the hospital laboratory (r = 0.77; p < 0.001). Similarly, mean +/- SD POC INR did not differ significantly from the laboratory-determined INR (2.45+/-0.59 vs. 2.37+/-0.48, respectively; p = 0.176). Regarding clinical accuracy, the values clinically agreed in 85.4% of the cases. CONCLUSIONS: The AvoSure PT Pro POC system appears to be useful for INR values within the 2.0-3.0 range, but values outside of this range should probably be confirmed with a standard laboratory method.